Q: What standard features come on all Toshiba motors?
A: All Toshiba motors include standard features such as cast iron frames,
oversized bearings, precision balancing and high-grade insulation.
Q: Do Toshiba motors meet NEMA Design B minimum locked
rotor torque requirements?
A: Even with a 10% voltage drop, our motors exceed NEMA Design B minimum
locked rotor torque requirements. In fact, most of our ``off the shelf standard
and premium efficiency motors meet NEMA Design C torque requirements which
eliminates the need for a special order motor.
Q: What is Toshiba's maximum allowable vibration level?
A: Toshiba's maximum allowable vibration level is 0.10 inch per second,
which allows for smoother and quieter operation resulting in longer motor life.
Our precision balance helps to lower bearing temperature rise, bearing wear, and
the risk of down time due to bearing failure.
Q: Do Toshiba motors allow for multiple starting methods?
A: Our motor designs with multiple leads allow for a variety of starting
methods. 12 lead, dual voltage motors are suitable for Across-the-Line starting,
Wye-Delta starting, and Part-Winding starting (on low voltage only). Multiple
leads allow for motor usage on 208, 230 or 460 volt systems.
Q: Are Toshiba motors ``Inverter Compatible?
A: Toshiba's EQPIII series motors have been designed for use with
adjustable speed drives. Low temperature rises, upgraded insulation systems
(NEMA MG1 part 31), improved magnet wire, and proper application support are
required for the reliable use of motors with PWM inverters. Toshiba motors and
adjustable speed drives are all manufactured under one roof, with careful
engineering, coordination and testing to ensure total system compatibility.